EasyManuals Logo

DMP Electronics 7800 Series Installation And Programming Guide

DMP Electronics 7800 Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
26 7800 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
Site Code Position and Length
Enter the site code start position and length in the data string.
Press select area 2 to clear the site code start position and
enter a number between 0-255. Press CMD to save. Default
is1.
Press select area 4 to clear the site code length and enter a
number between 1-24. Press CMD to save. Default is 8.
User Code Position and Length
Define the user code start bit position and length. Press select
area 2 to clear the user code position and enter a number
between 0-255. Press CMD to save. Default is 9.
Press select area 4 to clear the user code length and enter a
number between 16-64. Press CMD to save. The default is the
DMP value of 16.
SITE CODE
POS: 1 LEN: 8
USER CODE
POS: 9 LEN: 16

Other manuals for DMP Electronics 7800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics 7800 Series and is the answer not in the manual?

DMP Electronics 7800 Series Specifications

General IconGeneral
BrandDMP Electronics
Model7800 Series
CategoryKeypad
LanguageEnglish

Related product manuals