Introduction XT30/XT50 User Guide 11
When you arm the system, activity on all burglary zones is ignored
until the programmed exit delay time expires. Once that time has
expired and the system is fully armed, opening the door causes the
panel to start the entry delay time. During the entry delay time,
enter a valid user code to disarm the system or an alarm occurs.
Instant Zone
Exterior windows and non-entry doors, or interior protection
devices, are typically not programmed with delay times. If these
zones fault while the system is armed, an alarm occurs instantly.
24-Hour Zone
A 24-hour zone is not turned on or off by arming or disarm ing your
system. Some examples of 24-hour zones are re zones, panic
zones, and temperature control zones.
Areas
An area is made up of burglary zones that can be armed or disarmed
together. The Perimeter area, for example, consists of all the doors
and windows on the outside of the building. When you arm the
Perimeter, these zones sound an alarm if tripped.
Central Station Monitoring
Your system can also be programmed to automatically send alarm,
trouble, and arming and disarming reports to a central station.
Operators at the central station can then dispatch the appropriate
authorities or contact you with the specic event information.
Status
Status is a feature that automatically displays the system armed
or dis armed status on the keypads. Alarm or trouble con ditions on
a zone or a system monitor such as AC or battery trouble can also
display. There are two types of status information available: Status
List and Armed Status.
Status List
The keypad Status List displays any alarm or trouble condition on
a zone and any trouble condition that occurs with the AC power or
battery power. If your system contains any Panic zones, these do
not display on the keypad for security reasons.
If an alarm occurs on a non-re, 24-hour zone or a system monitor,
it remains in the Sta tus List until it re stores. If one or more armed
burglary zones trips, the last one to trip remains in the Status List.
The burglary zone alarm remains in the Status List until it is cleared
by disarming the system.
Zone Status
To display the status of a particular zone, enter the zone number
followed by the CMD key when the keypad displays the Status List.
Armed Status
With Armed Status, the keypad displays the current armed condition
of areas within your security system.
The keypad displays When
HOME SYSTEM ON The perimeter areas is armed in a
Home/Away system.
PERIMETER ON The perimeter is armed in an All/
Perimeter system.
ALL SYSTEM ON All areas are on.
SLEEP SYSTEM ON The perimeter and interior areas are on
but the bedroom area is off.
Also, for keypads that include an Armed LED, the Armed LED is ON
steady anytime a burglary protection area is armed and OFF when
ALL areas are disarmed.

Table of Contents

Other manuals for DMP Electronics XT50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XT50 and is the answer not in the manual?

DMP Electronics XT50 Specifications

General IconGeneral
BrandDMP Electronics
ModelXT50
CategoryControl Panel
LanguageEnglish

Related product manuals