"Beep", and at this time, hold the rocker lever to retract the strap and
Fully Automatic(AUT): Short press the button Tensioning until the set tension grade is
reached, and the tool will automatically weld and cut off the strap.
The strap welding will be finished after three short sounds of "Beep",
and at this time, hold the rocker lever to retract the strap and remove
5.2.5 Operation Essentials For Three Modes
Item Manual
Mode(MAN)
Semi-Automatic
Mode(SEM)
Full-Automatic
Mode(AUT)
a. Install the battery 1. Inset the charged battery into the battery slot, completed after a sound
of “Click”.
2. The display lights are ON, displaying all the previously set data, and
the blue light is always on, going to the standby mode.
b. Strapping 1. Place the strap
around the object to
be strapped.
2. Long press the
button Tensioning
for strap retraction
until your desired
tension is reached.
3. Press the button
Welding for friction
welding process, the
purple light short
on, and one long
sound of “Beep”,
the strapping
finished.
4. An emergency
stop or strap
retraction can be
achieved by lifting
the rocker lever
during the strapping
process.
5. The machine
goes into the
standby mode (the
blue light always
1. Place the strap
around the object to be
strapped.
2. Long press the
button Tensioning for
strap retraction until
the set tension is
reached, and then the
machine will carry out
friction welding
process automatically,
the purple light short
on, and three short
sounds of “Beep”, the
strapping finished.
3. An emergency stop
or strap retraction can
be achieved by lifting
the rocker lever during
the strapping process.
4. The machine goes
into the standby mode
(the blue light always
on).
1. Place the strap
around the object to be
strapped.
2. Short press (releasing
immediately) the button
Tensioning for strap
retraction until the set
tension is reached, and
then the tool will carry
out friction welding
process automatically,
the purple light short
on, and three short
sounds of “Beep”, the
strapping finished.
3. An emergency stop or
strap retraction can be
achieved by lifting the
rocker lever during the
strapping process.
4. The machine goes
into the standby mode
(the blue light always
on).
c.Idle for 30 seconds 1. The operation panel of the machine will be locked with a sound of
"Beep" after 30 seconds without any operation.
2. Long press the key DEC (for about 2 seconds), and you can unlock it
by pressing the button Welding (B1) after a sound of "Beep". (If it is not
necessary to set parameters, it is not necessary to unlock the panel,
because the machine can work in this case).
3. Strapping (the same as Item b).
d.Idle for 120 seconds 1. The machine will go into the sleep state with a sound of "Beep" after
120 seconds without any operation. Any button/key is invalid, except the
button Tensioning, in this case;