Rocker lever/Handle:
Holding up the rocker lever, you can lift
the tension wheel; retract the strap or stop
the machine in an emergency.
5.2.2 Basic Settings
Mode
selection(MODE)
After the operation
panel unlocked, you
can cycle to select a
mode you need by
short pressing the
button MODE.
Manual mode (MAN): Tensioning function and welding
function will be operated separately. Press and hold the button
Tensioning A until the set tension force is reached and then
press the button Welding B for manual strap welding & cutting
Semi automatic mode (SEM): Long press the button
Tensioning A, and the straps will be tensioned and welded one
time.(The tension wheel will stop rotating if the button
Tensioning A is released during the tensioning process, and at
this time, the tool will start welding and cutting off the strap if
the button Welding B is pressed.)
Fully automatic mode (AUT): Short press the button
Tensioning A, and the machine will automatically tension, weld
and cut off the strap. Under this mode: The strap will be
tensioned automatically, and will be welded and cut off
automatically when the tension grade re
Tension force
setting(SET)
After the operation
panel unlocked:
Adjust the strap
tension range
(Grade 1-9) by
short pressing the
button SET. The
larger the number
is, the stronger the
tension force will
be; and the weaker
on the contrary.
(Grade 1 stands
for the minimum
tension force, and
Grade 9 for the
maximum.)
The default
factory setting of
the machine is
Normal Mode H.
Normal Mode (H- -):
Tension force range: 400-2800N (adjustable, the tension force
of the tension wheel can reach 4200N.)
Grade: 1-9
Instruction: This mode is used when objects to be strapped are
required to be strapped relatively tightly (or when a PET strap is
used).
Note: in the Normal Mode, please adjust the tension force
for your desired one by increasing the tension force from the
minimum in sequence; and avoid the maximum grade, as
the tension force at this grade is the strongest, a strap can't
bear it, which will cause personal injuries of the operator.
Soft Mode (L- -):
Tension range: 400N-1600N