User Information Ringlock Safety Harness Connection Point
999817902 - 11/2020
39
Connection to a Ledger
Standard
Ledger
Safety harness
connection point
Pig tail pin/Toggle pin
The Ledger is a proper connection point for the Scaf-
fold Hook attached to a Lanyard. It is recommended
thatnomorethanonesca󰀨olderbeattachedtoany
Ledger at the same time.
Both Ledger ends must be attached with tightened
wedges to a Standard that is supported by two or
more Ledgers attached to the same rosette. To ensure
a positive connection is created it is recommended
that joints between Standards are pinned together
(ensure site local regulations and current Legislation
are followed).
Diagonal braces must be installed as per Doka rec-
ommendations and/or engineering design and they
mustbeinstalledasthesca󰀨oldiserected.Diago-
nal braces may not be used as harness connection
points.
Free fall distance should be limited to 2.0m (6’-6”) or
less in accordance with current Safety Guidelines for
thespecicconditionsofthefallhazard.Inaddition,
thesca󰀨old-specicfallprotectionplanshouldensure
that all fall zones are clear and unobstructed and that
ane󰀨ectivesca󰀨olderrescueplanhasbeendevel-
oped that can be mobilized quickly in the event that
an arrested fall incident occurs.
All persons using fall protection systems must be
trained in the proper installation and safe use of fall
protectionequipment,asrequiredbyWorkatHeight
Regulations.
Contractors and their employees must comply with
the Work at Height Regulations.
Sca󰀨oldersshoulduseanappropriatesafetyhar-
ness at all times such that the individual stays fully
protectedfromfallingwhenworkingatheights,Scaf-
folders should use suitable safe zones as per TG4
(currentrevision),atalltimes.
Sca󰀨oldersshouldhookonimmediatelyafterstep-
pingo󰀨aladderorothermeansofaccess.Doka
recommends the use of a properly installed Davit
Arm and retractable lanyard to ensure that workers
aretied-o󰀨whileclimbingexterior.
When it is necessary to reach below the single
guardrail(e.g.xingbracingorhandlingothermate-
rials).
- Clip to:
- Available and adequate steelwork.
-Standards,butreferto“SafetyHarnessAttach-
ment Guidelines”.
- Do not clip to:
- Ringlock Bay Braces.
- Standards not supported by two or more Ledg-
ers attached to the same rosette.
- Puncheons or cantilevered components.
-Pipework,plantguardrails,cableracksetc.
Refer to “Safety Harness Connection Guide” for suit-
able/appropriate harness locations.
Anchor points should always be as high as possible.
However,thisisnotalwayspracticalinsca󰀨olding
whichisusuallybuiltfromthegroundup.Ourrec-
ommendation is that where no higher anchor point is
available you should clip to the Ledger immediately
belowyourfeet.Thereissu󰀩cientspacebetween
the Ledger and the platform to clip on with a safety
harness carabiner.