AppendixIVDefaultParameters
Parameter Value DataType
CoolControlSetpoint 45 °F
HeatControlSetpoint 110 °F
SeawaterPumpControl Bydemand
FactorySettings
ControlTempmode CCWReturn
ControlValue Average
Modules 1
LowVoltageDetection No
HeatSupTemp No
CondRefrgTemp No
ElectricHeat Yes
ElectricHeatFlowSwitch Yes
LoadShedding Yes
ModeSwitch Yes
SWPumpCurrent No
CWPumpCurrent No
CompressorCurrent No
ExpansionValve Yes
Refrigerant R410a
SHControl T/T
DischargePressure No
SuctionPressure Yes
TempSensorCurve
CWReturn 10k
CWSupply 
ElectricHeatSetup
OnDelay 10 Seconds
DelayBtwHeaters 30 Seconds
RotationHours 0 Hours
CWPumpSettings
FlowProveDelay 10 Seconds
OffDelay 5 Seconds
SWPumpSettings
OffDelay 5 Seconds
Control Bydemand
CompressorSetup
Mode Cool+Heat
CompType 1Stage
PumpCompDelay 10 Seconds
MinOn 10 Seconds
MinOff 10 Seconds
DelayBtwComps 30 Seconds
RotationHours 1 Hour
RVDelayTime 5 Seconds
RVToggleOn 2 Seconds
RVToggleOff 2 Seconds
SupplyHighTemp 125 °F
Differential 20 °F
SupplyLowTemp 38 °F
Differential 4 °F
SupplyReturn
Differential 14 °F
AlarmDelay 120 Seconds
AlarmSetup
HighPressureSensorSP 550 PSI
LowPressureSensor
HeatMode 78 PSI
HeatMode 60 PSI