EasyManuals Logo

Domino G50i User Manual

Default Icon
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Alarm Beacon
An alarm beacon can be connected to let users monitor the printer's status from a distance.
# Value Description
5 24 V 24 V DC electrical power output.
Protected by a 3 A fuse.
Maximum current output: 1.5 A.
7 STOP Output to activate red beacon light.
Active low, open drain output.
47 K Ohm internal pull-up resistor to +24 V.
When this output is active, the printer has stopped printing
because of one of the reasons below:
No ink cartridge
Invalid ink cartridge
Empty ink cartridge
Speed limit
VDC/Real Time Printing Speed Overload
9 RUN Output to activate green beacon light.
Active low, open drain output.
47 K Ohm internal pull-up resistor to +24 V.
This output is active when one of the reasons below occurs:
The user has selected the "Print" button.
The printer is printing with no problems.
15 ALARM Output to activate green beacon light.
Active low, open drain output.
47 K Ohm internal pull-up resistor to +24 V.
This output is active when the printer has a problem, but it is still
able to print. For example, the ink level may be low.
INSTALLATION
EPT077343 EN - Issue 1 - 11 November 2022 59

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Domino G50i and is the answer not in the manual?

Domino G50i Specifications

General IconGeneral
BrandDomino
ModelG50i
CategoryPrinter
LanguageEnglish

Related product manuals