Page #37 background imageLoading...
Page #37 background image
DORMA CS 80 MAGNEO
37
01462 477 602
GB
Please call the following number in case
of technical problems or further questions:
Malfunction
The red LED blinks 4
times at regular
intervals.
The red LED blinks 5
times at regular
intervals.
The red LED blinks 6
times at regular
intervals.
The red LED blinks 10
times at regular
intervals.
Humming noise while
door is in end
position.
The door panel
vibrates when moving.
Possible cause
Testable safety sensors are
defective.
Damaged sensor cable.
DIP switches 1 to 3 are not set
correctly.
Incremental encoder or cable of
incremental encoder is defective.
The opening width is adjusted
incorrectly.
There is an obstacle within the
door s movement range.
The opening width has been
adjusted incorrectly.
Stator or cable of stator is
defective.
Short circuit at the terminal
connection.
Inappropriate end position of
door panel.
The guide mechanism is under
tension.
Remedy
Check and replace safety sensors
if required.
Check and replace cables if
required.
Check settings of DIP switches
and readjust if required.
Switch mains switch off and on.
Replace operator.
Readjust opening width
(end stops).
Remove obstacles from
movement range.
Readjust opening width (end
stops).
Start learning cycle (Page 31).
Switch mains switch off and on.
Replace operator.
Start learning cycle (Page 31).
1. Remove the short circuit.
2. The operator has to be
switched off and then on with
the aid of the mains switch.
Shift end stop by at least 2 mm.
Start learning cycle (Page 31).
Readjust the door panel
connection and the floor guide if
required. Turn the nuts several
times in order to fix the door
panels.
Operating cycle indicator
When you press the "Reset" button on the control unit for a short time, the door will open. In
case the LED light indicator lights up for one second (yellow light), the system has performed
more than 200,000 cycles.
You should contact the Service Department in order to have the system checked.
In case a defective operator has to be replaced, please contact your authorised dealer at the
respective point of purchase with the respective proof of purchase. However, you have to
consider that the complete basic operator including carriers has to be returned

Other manuals for Dorma CS 80 MAGNEO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dorma CS 80 MAGNEO and is the answer not in the manual?

Dorma CS 80 MAGNEO Specifications

General IconGeneral
BrandDorma
ModelCS 80 MAGNEO
CategoryDoor Opening System
LanguageEnglish

Related product manuals