DORMA CS 80 MAGNEO
28
94
95
96
1
3
31
3
34
1
3
15
3
13
1
3
11
3
13
1
3
41
3
1
3
42
3
Power supply for external
accessories 27 V DC, max. 700 mA
8. Connection diagrams (Only for properly qualified staff!)
not assigned
not assigned
not assigned
+27VDC
GND
Automatic
GND
Permanent
Open
+27VDC
GND
GND
Safety sensor test
+27VDC
GND
GND
Safety sensor test
+27VDC
GND
GND
+27VDC
GND
GND
Program switch (optional)
Remove jumper before a program switch
will be installed
Safety sensor for secondary closing edge
Remove jumper before a sensor
will be installed
Safety sensor for main closing edge
Remove jumper before a sensor
will be installed
Internal activator inside
(e.g. radar motion detector / pushbutton)
External activator
(e.g. radar motion detector / pushbutton)
Approach in case of a short circuit at the connection terminal
1. Remove short-circuit.
2. Switch mains switch off and on again.
In order to facilitate the connection of the
wires, the different terminal blocks can be
removed with pointed pliers.
Connection terminals

Other manuals for Dorma CS 80 MAGNEO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dorma CS 80 MAGNEO and is the answer not in the manual?

Dorma CS 80 MAGNEO Specifications

General IconGeneral
BrandDorma
ModelCS 80 MAGNEO
CategoryDoor Opening System
LanguageEnglish

Related product manuals