Technical Data
Operator
Line Input 100 to 125V AC, 60 Hz, 2 A max.
Power supply for external sensors 24 V
DC, 0.8 A
Fuse 2 A fast blow
Ambient Temperature 77 °F(25 °C)
Opening time to Back-Check 2.8 s 8 s
Closing time to Latch-Check 3.0 s 7.5 s
Delay before Opening 0 s 3 s
Delay before Closing 5 s 25 s
Back-Stop Angle 60° 120°
Back-Check-Angle 50° 120°
Latch-Check-Angle 10° 30°
Wall-Mask-Angle 60° 115°
Extra Power Hold Torque 40 ft-lb 240 ft-lb
Door height 84" 102"
Door weight 60 lbs (27 kg) 200 lbs (90 kg)
Door mount - single Push or Pull (Surface Applied)
Door width 37" 49“
Door mount - pair Push or Pull (Surface Applied)
Door width 62" 98"
Adjustments min. max.
Door min. max.
Controller Technical Data
Power input
Connector 2-piece terminal block
Line Input 100 to 125Vac, 60 Hz, 2 A max.
Fuse 2 A, fast (5mm x 20mm)
DC power out 24 Vdc, 800 mA out, always on,
short circuit protected, not regulated
Control inputs
Connector 2-piece terminal blocks
Active low inputs:
Open-Trigger (radar or push plate)
Presence, jamb mounted sensor
Safety Side, door mounted sensor
Approach Side, door mounted sensor
Hold-Open
Off
Safety Beam Sensor
Polarity active low or closed contact to
ground
Active threshold < 0.8 Vdc
Inactive threshold > 2.0 Vdc
Closed contact current 10 mA surge, 1 mA steady
state
Open circuit voltage 5 V
ESD protection ±5 KV, human body model
Overvoltage protection ±5 Vdc or 5 Vac, continuous,
with respect to GND
Smoke (Kill) link input:
Polarity normally closed contact to
GND
Closed contact current 2 mA
ESD protection ±5 KV, human body model
Overvoltage protection ±5 Vdc continuous, with
respect to GND
Indicators 1 LED/Sensor, 3-Digit Display
1-8 +24V
9 Electric Strike -Output
10 Data (Zone) -Output
11 Trigger (or radar or push plate) -Input
12 Presence (jamb mounted sensor) -Input
13 Safety Side (door mounted sensor) -Input
14 Approach Side (door mounted sensor) -Input
15 Safety Beam -Input
16 Kill (Smoke) link -Input
17-24 GND
Program switch
3 Hold Open - Input
2 GND
1 OFF - Input
Breakout
1 Breakout Switch -(N.C.)
2 GND
Motor
1 M+
2 M-
Power Input
1 Neut.
2 Earth Ground
3 Hot 100 to 125 VAC, 60 Hz, 2 A max.
Terminal Designations