Commissioning
8 Commissioning
1. Requirements
• The operator is mounted correctly, mechanically and electrically.
• The area of movement of the door leaf is free from obstacles.
• The door is in the half-open position
.
• The connections of the safety sensor system are bridged on the SIAK input
terminal block (optional).
• The operating mode switch is in O f f mode.
8.2 Safety during commissioning
CAUTION
Danger of injury from moving parts!
During commissioning there is a risk of crushing in the operator and
risk of being hit by the door leaves.
• During commissioning, do not touch the moving parts in the operator.
• Before commencing commissioning, ensure that nobody is in the area
of movement of the door leaves.
8.3 Commission the operator
WARNING
Danger of death due to electric current!
Touching live parts will result in death or serious injury from electric
shock.
• Work on electrical units must only be carried out by qualified
electricians.
• Before starting work on electrical units and equipment, establish a
voltage-free state and maintain this state for the entire duration of
the work.
• Do not touch live parts or cables.
• Suitable personal protective equipment must always be worn when
working with the product.
ES 250 PRO Easy
2024-03
53
ES250ProEasy Installation Manual