Product description
3.4 Technical data
230 V 50 Hz +10%/-15%Connection voltage:
10 AFuse supplied by the customer:
IP 20Protection class:
93 % relative humidity, non-
condensing
Permissible humidity:
-20°C to +60°COperating temperature:
27 V DC/max. 1 A short-circuit-proof
27 V DC/max. 1 A short-circuit-proof
Power supply
for external devices
- for mains operation:
- in the event of a mains failure in
battery mode:
27 V ±15 %
Multiport inputs
3.5 Closing edge protection
Warning
Only safety sensors with type approval according t o EN 16005 may
be used!
3.6 Secondary closing edge protection
If the distance of the opened door leaf to a stationary obstacle (e.g. a wall) is
smaller than 200 mm, the secondary closing edge must be protected, for example
with safety sensors or a protective panel.
9ES 250 PRO Easy
2024-03
ES250ProEasy Installation Manual