2. Enter the User Combination.
3. If required, present and click the button on the user fob when requested.
4. If required, enter User #2 credentials.
5. If this is the user’s first time opening a lock, the Keypad display interface will ask the User to change their original
combination. Input a new combination with the keypad. Re-enter the same combination to confirm.
Note: The new Combination must be different from the old Combination. The User is advised to use a non-trivial
combination.
6. The lock’s latch will open and the screen will display Lock Open. After 3 seconds, the lock’s latch will close.
If Time Delay is in effect, menus will be different. Consult the Time Delay section in this document for more information.
3.3.4 Open a Lock – Non-Display Keypad
Follow these steps to open a safe lock on a non-Display Keypad:
1. Enter the User ID and Combination.
2. If this is the User’s first time opening a lock, the Keypad will require a new Combination. Using the Keypad keypad,
input #52 + Authorized User ID and Combination + User ID and new Combination + User ID and new Combination
again + Return Key.
3. The lock’s latch will open. After 3 seconds, the lock’s latch will close.
If Time Delay is in effect, the lock will not automatically open.
3.3.5 Open a Lock – Remote Disable
With the application of the Alarm Box, the opening sequence can be disabled by asserting a signal on the Alarm Box. The
signal may come from an external alarming system that could feed into this lock to prevent it from opening.
Please observe the following while using the Remote Disable:
• The Remote Disable assertion will not block users from accessing the menus on a Display Keypad
• The signal must be asserted prior to the user authentication for it to be recognized by the system
• Duress combinations will still trigger the alarm signal, even if Remote Disable is asserted
• An Keypad with a display will show ‘Lock #x NOT open’ when the Remove Disable is asserted. The ‘x’ would be
replaced by a lock that is targeted to be opened
3.4 Reinstall Keypad
A new Keypad can be installed into the system if the current one is defective or needs to be replaced. If the new Keypad
is a non-Display screen variant, a command sequence would need to be followed with an authorized user. If the Keypad
has a display screen, prompts will appear to guide the user through the process. An Audit will be generated to indicate
which user installed the new Keypad. Once paired, the system returns to regular operation. Refer to the Keypad
Installation Guide (Document #7033.0320) for more information.
Note: The system will only recognize the same Keypad model as before, otherwise it will reject the reinstall process. If
installing a new model of Keypad, all locks attached to the system must be reset/uninstalled and reinstalled prior to
installing the new Keypad.
3.5 Change Combination
3.5.1 Change Combination – Display Keypad
Follow these steps to change a User combination on a Display Keypad:
1. From the Keypad display Main Menu, select Change combo.
2. New Combo appears on screen. Input a new combination with the number pad.