3.11.2 Open a Lock During Time Delay
3.11.2.1 Open a Lock During Time Delay Display Keypad
Follow these steps to open a safe lock during a Time Delay on a Display Keypad:
1. Using the Keypad, input the User ID and Combination.
2. For multi-lock systems, select the corresponding lock number on the keypad. Otherwise, skip to the next step.
3. Lock # Start Delay will appear on screen and provide timer feedback. The type of feedback depends on the setting
for count feedback (the time may count down, up, or only show time remaining). There is no continuous feedback; a
key must be pressed to check the Time Delay status. When a key is pressed on a Display Keypad, the ‘most urgent’
lock will be displayed.
a) Most Urgent Lock: In a single lock system, the Time Delay status is for a single lock, in a multi-lock
system, the status will be provided for i) the lock with the least amount of time remaining in the
confirmation window, or ii) if no lock is in the confirmation window, then the lock with the least amount of
time remaining will be present in the delay window
4. Once the Time Delay period expires, Lock # status Confirm appears on screen.
5. If a lock is in the confirmation window, it can be opened. Press a key to exit the Time Delay Status.
6. Input the User ID and Combination.
7. From the sub-menu, select Open Lock.
a) For multi-lock systems, select the corresponding lock number on the keypad. If the selected lock has
Time Delay enabled and i) is not already in Time Delay, Time Delay will start for the lock, and ii) is already
in Time Delay and the confirmation window, then the lock will open
8. The lock will open and the screen will display Lock Open. After a few seconds, the lock will close.
3.11.2.2 Open a Lock During Time Delay Non-Display Keypad
Note: This function is not available on the 701 series of Keypad,
Follow these steps to open a safe lock during a Time Delay on a non-Display Keypad:
1. Using the Keypad, input the User ID and then the Combination.
2. The Keypad will beep and flash a red LED once every 10 seconds during the Time Delay period.
3. The Keypad will then beep and flash a green LED once every 10 seconds during the Confirmation Window,
signifying the safe lock can now be opened.
4. Input the User ID and Combination.
5. The lock will open. After a few seconds, the lock will close.
3.11.3 Cancel a Time Delay
3.11.3.1 Cancel a Time Delay Display Keypad
Follow these steps to cancel a Time Delay on a Display Keypad:
1. While a safe lock is currently in a Time Delay, press the Return Key on the Keypad.
2. Input a valid User ID and Combination.
3. From the sub-menu, select Cancel TD.
a) For multi-lock systems, select the corresponding lock number on the keypad
4. Lock Dly Cancelled will appear on screen and the Keypad will beep three times and flash a green LED.
3.11.3.2 Cancel a Time Delay Non-Display Keypad
Note: This function is not available on the 701 series of Keypad,
Follow these steps to cancel a Time Delay on a non-Display Keypad:

Table of Contents

Other manuals for Dormakaba LA GARD 705

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dormakaba LA GARD 705 and is the answer not in the manual?

Dormakaba LA GARD 705 Specifications

General IconGeneral
BrandDormakaba
ModelLA GARD 705
CategoryLocks
LanguageEnglish

Related product manuals