dormakaba USA Inc. System User Guide 7040.0321 | 34
3.12.2.2 Critical Low Battery Warning – Non-Display Keypad
When using a Keypad without a Display screen, on wake-up key press, the Keypad will emit 3 high beeps and 3 green
LED flashes followed by 3 low beeps and 3 red LED flashes. The System will not respond to any other commands until
the battery is replaced.
3.12.3 Replacing Batteries in Critical Low Battery State
When in Critical Low battery state, and the batteries are within the secure container, the system must do a restart when a
battery (or batteries) is applied to the Keypad. The restart can be forced by pressing the # key when the new battery is
applied to the Keypad. The safe should be opened and the inside batteries replaced.
3.13 Wrong Try Penalty
The Wrong Try Penalty occurs when a User inputs a credential incorrectly 4 times in a row. The penalty period is for 5
minutes, within that time no safe lock connected to the Keypad will open. All menu access and command inputs on the
Keypad will also be locked for 5 minutes. Once the 5-minute penalty is over, 2 consecutive incorrect credential inputs will
initiate another 5-minute penalty. Wrong Try Penalties do not apply to the Time Delay Override with Fob user.
For entries with display menus, the time will count down on the screen.
For non-display entries, 2 short low buzzes and 2 short red LED blinks will signify the penalty is still in effect.
Note: If power is interrupted to the Keypad during a Wrong Try Penalty, the time left will resume where it was when power
is re-applied.
3.14 View Audits (Display Only)
Note: This function is not UL evaluated.
Audits can be viewed on Entries equipped with a display. The Keypad will display Audit data, showing a code for the
action that occurred, the date and time when the action occurred and the ID of the User who performed the action. A User
must have Audit Privileges enabled to view this data. The Master User automatically possesses Audit Privileges. A
maximum of the latest 50 audits can be viewed on the Keypad display.
Follow these steps to view Audits on screen:
1. Navigate through the Main Menu and select Audits.
2. If using a multi-lock System, select the corresponding lock number on the keypad. Otherwise, skip to the next step.
3. Navigate through each Audit transaction with the Arrow buttons on the keypad.
To view the codes defined for each audit, please refer to Appendix B.
To retrieve Audits from a safe lock to the LA GARD Software client, refer to section 5.4 Retrieving Audits later in this
document.

Table of Contents

Other manuals for Dormakaba LA GARD 705

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dormakaba LA GARD 705 and is the answer not in the manual?

Dormakaba LA GARD 705 Specifications

General IconGeneral
BrandDormakaba
ModelLA GARD 705
CategoryLocks
LanguageEnglish

Related product manuals