dormakaba USA Inc. System User Guide 7040.0321 | 27
3.9.7.2 Duress Mode Non-Display Keypad
Note: This function is not available on the 701 model of Keypad.
Follow these steps to Enable/Disable Duress Mode on a non-Display Keypad:
1. Using the Keypad, input #14 + Master ID and Combination + Duress Mode (0 = Disabled, 1 = Enabled) + Return
Key.
2. The Keypad will beep three times and flash a green LED once complete.
3.10 Locks
Certain functions and commands can be carried out on the Keypad without the use of software. Entries without a display
screen can only have one safe lock installed at a time; they do not support a multi-lock setup.
3.10.1 Install a Lock
The process of installing a safe lock differs with single and multi-lock systems. For information and steps on how to
physically install a safe lock(s) to a system, whether single or multi-lock setup, refer to the Safe Lock Installation Guide
(Document #7034.0320).
3.10.2 Uninstall a Lock
3.10.2.1 Uninstall a Lock Display Keypad
Follow these steps to Uninstall a safe lock on a Display Keypad:
1. Navigate through the Main Menu and select System.
2. Select Locks from the sub-menu.
3. Select Uninstall.
4. Press the corresponding number key to select a lock.
Note: If only a single lock is installed, this screen will not appear.
5. Select either Yes or No to confirm.
Note: Confirmation is only required when uninstalling the last (primary) lock.
6. Success Uninstalled appears on screen and the Keypad will beep three times and flash a green LED once
complete.
Note: Lock #1 cannot be uninstalled until all other locks are uninstalled or reset.
3.10.2.2 Uninstall a Lock Non-Display Keypad
Follow these steps to Uninstall a safe lock on a non-Display Keypad:
1. Using the Keypad, input #23 + Master ID and Combination + Return Key.
2. The Keypad will beep three times and flash a green LED once complete.
3.10.3 Reset a Lock
Each LA GARD safe lock can be reset to factory defaults. This function is particularly useful when switching out a piece of
the overall System that has a different model number than the previous version. A lock reset can be done one of two
ways:
1. Master Reset via the Keypad (both Display and Non-Display versions)
2. Mechanical Reset via the Reset Box.
When a lock is reset, the Master Combination is reverted to the default (1-2-3-4-5-6-7-8) and all Managers/Users are
deleted. All System and lock settings will be reset to their defaults. All locks will be uninstalled and unpaired to any
Keypad.

Table of Contents

Other manuals for Dormakaba LA GARD 705

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dormakaba LA GARD 705 and is the answer not in the manual?

Dormakaba LA GARD 705 Specifications

General IconGeneral
BrandDormakaba
ModelLA GARD 705
CategoryLocks
LanguageEnglish

Related product manuals