Issued July 2024
Body Controller Softw are
Copyright 2024, The Heil Co.
Printed in the U.S.A.
Body Controller Software
131
Related Option Configurations
Option
Status
Functionality
Selected Truck Type
7000 OIN
Configures controller for DPF 7000, Operate in Neutral
Selected Truck Type
7000 OIGIA
Configures controller for DPF 7000, Operate in Gear at Idle
Selected Truck Type
Python OIGIA
Configures controller for DPF Python, Operate in Gear at Idle
Selected Truck Type
Multipack OIGIA
Configures controller for DPF Multi-Pack, Operate in Gear at Idle
Max. Spd Hyd. Pump
25 MPH default
1-45 MPH range.
Conditions Necessary to activate the circuit:
Condition
Logic
Function or Component
Status
I/O Address
Status
A
-
System Power Switch
Activated
%IX0.15
ON
B
AND
Critical Faults
Inactive
N/A
See 6.04.01(Beep Codes)
C
AND
Hydraulic Pump Enable PB
Enabled
%IX1.05
ON (momentary)
Note: With Condition (A AND B) true, Condition C will enable the hydraulic system. Hydraulic Pumps will operate in accordance with
the selected truck type and speed parameters.
Selected Truck Type (7000 OIN)
Condition
Logic
Function or Component
Status
I/O Address
A
-
Packer Extend Solenoid
Activated
%QX0.05
B
OR
Packer Retract Solenoid
Activated
%QX0.04
C
AND
Chassis Neutral
Deactivated
%IX1.04
OR
A1
-
Lift Pump (P1)
Activated
%QX0.14
Speed Parameters
Default Setting
Maximum Vehicle Speed
25 MPH
Maximum Engage Engine Speed
1500 RPM
Maximum Operating Engine Speed
1800 RPM
Note: With the hydraulic system enabled, condition ((A OR B) AND C) OR A1, will activate (Packer Pump) within the speed parameters.
Selected Truck Type (7000 OIGAI)
Condition
Logic
Function or Component
Status
I/O Address
A
-
Chassis Neutral
Activated
%IX1.04
B
OR
Packer Extend Solenoid
Activated
%QX0.04
C
OR
Packer Retract Solenoid
Activated
%QX0.05
D
OR
Lift Pump (P1)
Activated
%QX0.14
Speed Parameters
Default Setting
Maximum Vehicle Speed
25 MPH
Maximum Engage Engine Speed
1350 RPM
Maximum Operating Engine Speed
1800 RPM

Table of Contents