SECTION 4 - TECHNICAL INFORMATION
4-62
SmartDate 5 08/08
4.9.10 Controller PCB Links
The Controller PCB use various links to configure functions on the board.
The Controller PCB links are listed below:
Table 4– 8: Controller PCB Links
Link Description Function
X11 PG - Print Go Input
PNP Input
Position A - PNP
X12
IN1 - User Configurable
Input
PNP Input
Position A - PNP
X16 Run Bootstrap
Position A - Default
Position B - Forced program refresh
X21 Battery
Position A - Linked
Position B - Not Linked
4.9.11 Controller PCB Fuses
The Controller PCB is fitted with thermal resettable fuses.
The Controller PCB fuses are listed below:
Table 4– 9: Controller PCB Fuses
Fuse Description
F1 LCD Supply
F2 24V Supply
F3 24V SmartTouch Supply
F4 Fault Output
F5 Warning Output