SECTION 2 - SETUP AND TIMING ISSUES
2-15
SmartDate 5 08/08
2.8.5 SmartDate 5 - Continuous Mode and SmartDate 5s
The timing on the continuous printers is slightly different. It is not the Print Time
that is the critical timing but generally the Repeat Time.
2.8.6 Printing Time - Continuous Printers
The Printing Time (in the Timing menu) consists of the following:
Head Out time
Start Border
Print (Print speed set by Encoder)
End Border
Head In time
2.8.7 Print Cycle Time - Continuous Printers
On receipt of a print signal the whole print cycle is as follows:
Debounce Distance
Print Delay
Head Out time
Start Border
Print (Print speed set by Encoder)
End Border
Head In time
Return Speed