SECTION 3 - MAINTENANCE
3-18
SmartDate 5 06/08
3.11 Replacing the Ribbon Tension Sensor
If the tension sensor has to be replaced, the procedure should be as follows:
Switch off and disconnect the power to the machine.
2. Remove the sensor retaining screws
from the printer base plate.
3. Remove the sensor from the printer
body.
4. When fitting a replacement sensor,
ensure that the retaining screws are
secured with Loctite 222.
1. Remove the cover from the printer
body and disconnect the sensor
connector.
After fitting a new Ribbon Tension sensor, the sensor will require calibrating.
Please contact Markem.Imaje for details.