SECTION 3 - MAINTENANCE
3-9
SmartDate 5 06/08
3.6.2 Setting the correct Printhead voltage
Note the resistance value printed on the PCB side of the new Printhead. This
value must be entered into the controller menu structure.
The processor will then adjust the voltage level to suit the particular printhead
resistance level.
Each Printhead has an individual
Resistance level, and the voltage level
setting required for each is different.
A label on the printhead displays the
rating for that particular one.
In this case, R = 1272
The Printhead resistance option can be accessed from the Engineering menus.
To access the Engineering Menus:
1. From the Menus screen select Engineering.
1. Select Job
Menu
3. Darkness
4. Engineering
SelectBack