3.1.4 DPC Installation
Parts
Required
Part # Part Description
Remote
DPC
Pedestal
DPC
20-8225-DPC Remote DPC for Gibarco/Wayne Yes No
20-0612 DPC Interface Yes Yes
12-3004 Cable RJ45 to RJ45 Stranded 10-15 Ft. Yes Yes
20-1618
Cable, PCM Master (Power Cable [C/OPT or
FIT500])
No Yes
3.1.5 DPC Pump Control (Electronic Control) Conduit Requirements
Conduit should be run from the FIT pedestal or Remote DPC to the pump junction box. This conduit should
only contain the Pump Control wires with the exception noted below. Wires required are per dispenser; if
conduit is running to two double-sided fuel pumps then two times the wire is required as shown below.
Wires (per fueling
point)
Wire Requirements
Pump Control*
Two wires - must meet pump manufacturer's specification for the controlled
pump.
*NOTE: When using manufacturer’s D-Box, only two wires need to be pulled to the D-Box for all
pumps.
Depending on your specific site installation requirements and brand of dispenser, please refer to the
applicable DPC installation instructions.