3.1.6 DPC Interface in a Remote Enclosure (for Wayne and Gilbarco)
NOTE: The 20-8225-DPC assembly includes all internal wiring for the power supply and the
DPC interface board. Refer to the instructions that follow to install and connect external power
and communication wiring.
DANGER: To avoid the possibility of explosion, fire or electrical shock, de-
energize the system before you do this procedure.
1. Install the enclosure on a wall with four (4) fasteners (not supplied). The enclosure must be no further
than 50' (15.24 m) from the FSC3000 controller.
2. Install 1/2” or 3/4” rigid steel conduit for the DPC Power Supply.
3. Pull three (3) 14-AWG wires from the breaker panel.
4. Install 1/2” or 3/4” rigid steel conduit for pump communication.
5. Pull wires from each dispenser and Ethernet connection from the FSC.
M1700 FSC3000 Installation Manual | Dover Fueling Solutions 51