l For Gilbarco CRIND installation: RJ45 cable between the CN4 port of the DPC board to the CN3
(COM3) port of the DTC board (refer to Physical Configuration for correct connections for different
installations).
3.2.5 Physical Configuration
3.2.5.1 Wayne CAT-specific
Attach CAT communications wires to terminal blocks CN5 through CN8. For best performance, connect
each dispenser to its own terminal block. If there are (up to)12 CAT dispensers, connect a maximum of 3
dispensers to each terminal block.
Make sure the jumpers are set according to the diagram as shown above. The jumpers marked with “#”
connect termination resistors on the dispenser communication lines. Install these jumpers only if you
experience COMM errors with the dispensers.