Rev 0.0
Dr.coffee Service Manual 18
7.2.1.1 Grounds
Grinding gram level, setting level:15,details as below
The weight of this data is calculated according to the
factory default setting
.
The data is the experimental value for reference only. If the difference is subject
to actual conditions.
Tolerance
:±
1g
Comparison table
G
rounds 1 2 3 4 5
Gram 5g-7g 7g-9g 9g-11g 11g-13g 14g-16g
7.2.1.2 Pre-brewing times
The coffee powder pre-brewing time, unit: S, setting level: 0~5
7.2.1.3 Coffee volumeml
The amount of coffee flowing out, unit: ml. Setting level: See the screen numerical on
the interface, different beverage with different beverage value limits.
7.2.1.4 Hot water volumeml
The amount of Hot water, Unit: ml Setting range: Please refer to the screen value
input interface. Different drinks have different tolerance
7.2.1.5 Extraction method
Indicates to set the type of extraction method for coffee when making coffee.
Normal
when making coffee, the pump works at full frequency
Thickened
when making coffee, the water pump works intermittently.
Compared with the normal method, the extraction time will be longer
Deep
when making coffee, the water pump works intermittently. Compared
with the thickening method, the extraction time will be longer
7.2.1.6 Circle index
Brewer working times of beverage making. Choices: 1~5
7.2.1.7 Order
The order of material output during coffee making.
Coffee first: coffee out first, then others out;
Coffee last: Others out first, then coffee out;
7.2.1.8 Temperature level
Different temperature level, selection: Low, Medium, High.
High
The heating temperature of the coffee thermos-block is controlled at
around 102
℃(
if the NTC of thermos-block reaches 102
, heating stop ,if the
temperature lower than 102
starts heating
Medium
The heating temperature of the coffee thermos-block is controlled at
around 94
℃(
if the NTC of thermos-block reaches 94
, heating stop ,if the
temperature lower than 94
starts heating
Low
The heating temperature of the coffee thermos-block is controlled at
around 86
℃(
if the NTC of thermos-block reaches 86
, heating stop ,if the
temperature lower than 86
starts heating
Test after modifying any parameter, click the "Test" button to make a drink according
to the drink parameter value displayed on the current interface
Save after all parameters are modified, click the "Save" button to save
Technicup Service Manual

Table of Contents

Related product manuals