Dr.coffee Service Manual 32
9.1.2 Brewer System Error
Name
Showing on the Screen Cause Solutions
Brewer
System
Error
a) Tap three times brewer self-checking
prompts brewer system error
b) The Brewer is blocked is stuck;
c) The motor doesn’t work;
d) The Brewer damages;
e) Control Board damages;
Switch off the machine and restart;
Disassemble the brewer , check and
clean;
Replace a new motor;
Replace a new Brewer;
Replace a new Control Board;
9.1.3 HMI Communication Error
Name
Showing on the Screen
Solutions
HMI
Commun
ication
Error
a) Main Board and display board connection
loose or damaged;
b) Control software doesn’t match with the
HMI software;
c) HMI PCB damages;
d) Main Board damages
Check the plugs on HMI PCB and
reconnect;
Upgrade Control software and HMI
Software;
Replace a new HMI PCB;
Replace a new Main Board.
9.1.4 Coffee Thermo-block NTC Error
Name
Showing on the Screen Cause Solutions
Coffee
Thermo-
block
NTC
Error
a) The temperature of the thermos-
exceeds settled value
b) Electronic fault between sensor and
master
c) Sensor damaged
Check line, re-install or replace;
Replace new NTC sensor;
Turn off machine and wait for 30 minutes,
turn on again;
Replace new thermos-block group.