Rev 0.0
Dr.coffee Service Manual 34
9.2.3 Software System Crashed
Showing on the Screen Cause Solutions
System
Crashed
No picture
a) The system stopped working and no
reaction unexpectedly;
Switch off the machine and restart after 5
minutes;
Update the Software;
9.2.4 Leaking
Name
Showing on the Screen Cause Solutions
Leaking No picture
a) Leaking at the inlet connector of machine
to Tap water ;
b) Leaking inside of machine;
Check if the connector is loosed;
Dissemble the cover of machine and find
out the place leaking;
Replace the parts leaking;