Rev 0.0
Dr.coffee Service Manual 28
8.1.4 Drip Tray Is Not In Place
Showing on the Screen Cause Solutions
Place
a) Not well fixed;
b) Sensor broken ;
c) Magnet loosing or broken;
Replace the drip tray;
Replace new sensor;
Replace new magnet;
8.1.5 Drip tray is full up
Name
Showing on the Screen Cause Solutions
is full up
a) The waste water in the tray is full;
b) Sensor is dirty;
Pull out and empty the tray;
Check and clean up the sensor;
8.1.6 Coffee Thermo-Block Over-heated
Coffee
Thermo-
Block
Over-he
ated
a) Temperature is over 160℃;
Wait, as the tips in the Screen “The hot
water thermos-block is cooling down,
please wait ...”;
While the thermos-block is cooling down,
no beverage could be made.
Technicup Service Manual