Rev 0.0
Dr.coffee Service Manual 30
8.1.10 Grinder Calibration
Grinder
Calibrati
on
a) After a certain cups of coffee made, it will
alarm;
It will alarm at the 2000th cup,
7000 th cup, 17000th cup,
27000th cup… and so on.( every
10 thousand cups)
Turn off, will not alarm
Follow the tips and enter service manual
to do finish calibration;
Follow the instruction of service manual;
8.1.11 Brewer Check Up
Showing on the Screen Cause Solutions
Brewer
Check
Up
a) The Brewer is not in a right position;
b) The Brewer damaged;
c) The drive motor of brewer damaged
Tap “Check Up”’
Replace a new Brewer;
Replace new drive motor;
8.1.12 Brewer Deep Clean Required
Name
Showing on the Screen Cause Solutions
Brewer
Deep
Clean
Required
a) Reach the set value, it will alarm. Set in
Manu;
The settled valve can be changed
in the service manual;
Follow the tips and enter service manual
to do deep clean;
Follow the instructions of service manual