Do you have a question about the Dräger Oxylog 1000 and is the answer not in the manual?

Dräger Oxylog 1000 Specifications

General IconGeneral
BrandDräger
ModelOxylog 1000
CategoryFan
LanguageEnglish

Summary

Safety and Patient Care

Follow Instructions for Use

Emphasizes strict adherence to all instructions for safe operation.

Maintenance and Servicing

Procedures for inspection, servicing, and repair by trained personnel.

Intended Use and Initial Setup

Device Intended Use

Describes the Oxylog 1000's purpose and applications in emergency settings.

Operating Concept and Controls

Front Panel Overview

Details rotary control knobs, switches, and indicators on the front panel.

Alarm Indicators and Muting

Explains the function of flag indicators for alarms and the audible alarm muting button.

Operation Procedures

Oxylog 1000 Device Check

Step-by-step guide for performing a device check before each use.

Ventilation Modes and Settings

IPPV Controlled Ventilation

For ventilation frequencies of 5 to 40 breaths per minute.

Presetting Ventilation Parameters

Using color-coded scales for setting Freq. and MV for patient groups.

Ventilation Operation Details

Patient Connection and Monitoring

Steps for connecting the patient and monitoring airway pressure during inspiration.

Special Ventilation Scenarios

Cleaning and Disinfection

Preparation and Assembly

Device Installation

Gas Supply Connection

Connecting the O2 Supply (Cylinder)

Safety precautions and procedures for connecting O2 supply via cylinder.

Gas Supply and Operating Time

Readiness Checks: Frequency

Connecting the Test Lung

How to connect the test lung to simulate patient ventilation.

Readiness Checks: Alarms

Testing Paw Upper Alarm

Procedure to test the upper airway pressure (Paw) alarm functionality.

Testing Paw Lower Alarm and Muting

Testing the lower Paw alarm and the audible alarm muting function.

Readiness Checks: Supply Pressure

Troubleshooting Common Issues

Faults, Causes, and Remedies

A table detailing faults, causes, and remedies for common issues.

Maintenance and Disposal

Technical Specifications: Environment and Performance

Performance Characteristics

Details operating principle, control, ventilation frequency, and volume specs.

Technical Specifications: Alarms and Gas

Alarm Triggers and Gas Supply

Describes alarm triggers, muting, and detailed gas supply requirements.