Summary

For Your Safety

Maintenance

Unit inspection and servicing by qualified personnel.

Explosion Hazard Areas

Requirements for equipment in explosion-hazard areas.

Accessories

Use of only approved accessories from the ordering list.

Intended Use

Product Design

Transmitter Features

Modular system with display, keypad, and optional interfaces.

Optional Extras

Pump and relay modules for enhanced functionality.

Installation Accessories

Daisy chain, duct extension, remote sensor, software dongles.

Installation Procedures

Preparing for Installation

Site selection, environmental factors, and gas properties.

Installing the Transmitter and Docking Station

Mounting the docking station and connecting the transmitter.

Installing Accessories

Procedures for adding daisy chain, remote sensors, and dongles.

Electrical Connections

2-Wire Connection

Connecting the transmitter using a 2-wire cable.

3-Wire Connection

Connecting the transmitter using a 3-wire cable.

HART Multidrop Connections

Connecting multiple transmitters via HART.

4-Wire Connection

Connecting the transmitter using a 4-wire cable.

Operation and Navigation

Start-up Procedures

Powering on, warm-up, and initial checks.

Basic Operating Procedures

Switching modes, entering passwords, navigating menus.

Menu Structure

Overview of main menus and submenus.

Maintenance and Calibration

Maintenance Intervals

Recommended inspection and service schedules.

Calibrating the Unit

Procedures for zero and span calibration.

Replacing the Sensor

Steps for sensor replacement.

Troubleshooting

Faults, Causes, and Remedies

Table of faults, causes, and remedies.

Warnings and Remedies

Table of warnings and their solutions.

Technical Data and Certifications

Technical Specifications

Electrical, ambient, and communication parameters.

Safety Approvals

ATEX, IECEx, UL, and CSA compliance details.

Declaration of Conformity