Metrological certificate of approval
122
(–) * Negative display.
ethylene C
2
H
4
2 Vol.-% ≤ 1 (–) *
ethine C
2
H
2
1 Vol.-% ≤ 0.5 (–) *
ethylene oxide C
2
H
4
O 20 ppm ≤ 2 (–) *
hydrogen fluoride HF 15 ppm no influence
formaldehyde HCHO 40 ppm no influence
carbon dioxide CO
2
5 Vol.-% no influence
carbon monoxide CO 100 ppm ≤ 0.1 (–) *
methyl methacrylate CH
2
C(CH
3
)COOCH
3
50 ppm no influence
methylamine CH
3
NH
2
100 ppm no influence
carbonyl chloride COCl
2
1 ppm no influence
phosphine PH
3
10 ppm no influence
i-propyl alcohol (CH
3
)
2
CHOH 500 ppm no influence
propylene CH
3
CHCH
2
50 ppm ≤ 0.2 (–) *
sulphur dioxide SO
2
20 ppm no influence
hydrogen sulfide H
2
S 20 ppm no influence
hydrogen selenide SeH
2
5 ppm no influence
hydrosilicon SiH
4
5 ppm no influence
nitrogen dioxide NO
2
50 ppm no influence
nitrogen monoxide NO 20 ppm no influence
styrene C
6
H
5
CHCH
2
30 ppm no influence
tetrahydrofurane C
4
H
8
O 60 ppm no influence
tetrahydrothiophene C
4
H
8
S 5 ppm no influence
vinyl chloride C
2
H
3
Cl 50 ppm no influence
hydrogen H
2
1 Vol.-% ≤ 1.5 (–) *
hydrogen peroxide H
2
O
2
5 ppm no influence
CAUTION
The influence of unsaturated hydrocarbons, alcohols or hydrogen in higher concentrations or over a longer period of
time (dose approx. 100,000 ppm x hours) will let the sensor drop out.
When used in transmitters with pump module, the O
2
LS sensor (68 09 630) must always be installed at vibration-free
locations. If used in this combination, vibrations may cause the measured value to deviate outside of the permissible
range.
Gas / vapour Chemical symbol Gas concentration Measurement value devia-
tion in Vol.-%
with dust filter