The menu » Settings «
The » dynamic « signal type is an AC signal with the following characteristic:
– Maintenance level
This function is used to set the current on the analogue interface for the
maintenance signal » «.
Select the menu items » Settings «, » Communication «, » Analogue
interface « and » Warning level « in this order, pressing the » « key after
each selection.
Use the » « and » « keys to set each position of the current value and
press the » « key to confirm the setting.
Press the » « key to confirm the complete current value.
– Offset current
Provides for the adjustment of the zero point signal (4 mA signal).
Select » Settings «, » Communication «, » Analogue interface « and
» Offset current « in this order, pressing the » « key after each selection.
Use the » « key for marking the input value for the current value and se-
lect it with the » « key.
Use the » « or » « keys for selecting the desired sign (+/-) for the in-
put.
By pressing the » « key, select the desired input field and enter the de-
sired current correction value with the » « or » « keys. A maximum
input of +/- 0,500 mA of the factory-preset 4 mA current value is possible.
Press the »« key to confirm the completely adjusted current value.
05923758_1_de.eps
t
[s]
1,1
[mA]
0,7
5
3
OK
M
OK
OK
OK
M
OK
M
OK
M
OK

Table of Contents

Other manuals for Dräger Polytron 7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Polytron 7000 and is the answer not in the manual?

Dräger Polytron 7000 Specifications

General IconGeneral
BrandDräger
ModelPolytron 7000
CategoryAdapter
LanguageEnglish