Technical data
86 Service Instructions 171/173 - 00.0 - 01/2020
18.1 Data and characteristic values
18.2 Requirements for fault-free operation
Compressed air quality must conform to ISO 8573-1: 2010 [7:4:4].
Technical data Unit
0171-131610
0171-141621
0171-131610 + 550-121
0173-141610
0173-141521
550-2-2
550-15-5
Type of stitches 401
Hook type Crossline
Number of needles 1 (2) 1 1 (2) 1 2 1
Needle system 934 RG or 933
Needle strength [Nm] 80 - 130
Thread strength [Nm] 70/3
Stitch length [mm] 1 - 4 2.5 1 - 4
Speed maximum
[min
-1
]
6600 6000 2500 6000
Speed on delivery
[min
-1
]
6600 5800 2200 5800 5500
Mains voltage [V] 190 - 240
Mains frequency [Hz] 50/60
Operating pressure [bar] 6
Length [mm] 550 500
Width [mm] 175
Height [mm] 380
Weight [kg] 37 38 39 40 39
Power input [kVA] 0.5

Table of Contents