PP4 - Soft start
Number of soft start stitches
(min. = 0.. max. = 10; def. 5)
Soft start speed
(min. = 100 .. max. 2000; def. 300 U/min)
PP5 - Sensitivity of the needle thread monitor
(min.=0..max.= 99: def. 5)
Is only active when enabled with the machine parameters.
(The higher the value the less sensitive the upper thread
monitor will be.
99 = The upper thread monitor is switched off for this
program only.)
PP6 - Thread consumption
Material thickness (min. = 0.. max. 20.0; def. 0)
Thickness of the material when pressed together.
Adjustment of the thread consumption
(min. = -10.0.. max. 10.0; def. 0)
Correction of the calculated values.
PP7 - Move
The contour will be shifted in the requested direction
according to this value.
Move in X direction
(min. = -5.0… max. = 5.0; def. = 0 .0 mm)
Move in Y direction
(min. = -5.0… max. = 5.0; def. = 0 .0 mm)
PP8 - Scale
The size of the contour will be changed in the direction
desired according to this value.
Scaling in X direction
(min. = 80… max. = 120; def. = 100 %)
100% correspond to the original size.
Scaling in Y direction
(min. = 80… max. = 120; def. = 100 %)
32