Mode 5
The clamp remains closed in the feeding position.
After actuating the pedal one more time
the seam will be started.
Feeding position
(on/off)
With the feeding position activated the clamp
goes to the requested position in order to facilitate
the feeding of the material.
Feeding position X
(min. = -300… max. = 300; def. = 230 mm)
Feeding position Y
(min. = -300… max. = 300; def. = -90 mm)
PP3 - Deposit mode:
Deposit mode
The following modes can be set:
Mode 1 (def.)
The clamp will be opened in the deposit position.
Mode 2
The clamp remains closed in the deposit position.
After actuating the pedal the clamp will be opened.
Mode 3
The clamp remains closed in the deposit position.
After actuating the pedal the left part of the
two-piece clamp for an angular feed will be opened.
After actuating the pedal one more time the right side
will be opened.
Mode 4
The clamp remains closed in the deposit position.
After actuating the pedal the right part of the
two-piece clamp for an angular feed will be opened.
After actuating the pedal one more time the left side
will be opened.
Mode 5
The clamp remains closed in the deposit position.
Deposit position
(on/off)
With the deposit position activated the clamp
goes to the requested position after sewing in order
to facilitate the deposit of the material.
Deposit position X
(min. = -300… max. = 300; def. = 230 mm)
Deposit position Y
(min. = -300… max. = 300; def. = -90 mm)
1
31