9.2 Information messages
Info Description Remedy
8400 The control panel has no valid program for the DAC
Load the current program onto the
control panel with a USB-stick
8401
8402
The control panel has no valid program for the DAC
Load the current program onto the
control panel with a USB-stick
8403 The program in the DAC is no more up-to-date
Load the current program onto the
DAC
8404
-
8407
Faulty update of the DAC
- Re-try update
- Check the cable connection
- Replace the DAC
8408 Waiting for the reset by the DAC
Wait until restart is finished (takes a
few seconds)
8411 Checking of the DAC program active
Wait until checking is finished (takes
a few seconds)
8414 Successful update of the DAC
8801
-
8805
8806
8890
8891
Error testpins/ Signal- / Event processing/ Memory
wrapper /List of functions
Internal error
- Switch the machine off and on
again
- Software update
- Inform the DA-Service
System
9000 Reference run active
9002 Machine head not locked Lock the machine head
9006 Quick stop switch is actuated
Releasethequickstopswitch
9016 Wrong barcode-ID
Change the program
9100 The counter has not reached the preset value
Actuate the OK-key. The counter
will then be reset