9. Error messages/Information messages
9.1 Error messages
Error code Description Remedy
Sewing motor
1051 Sewing motor timeout
- Faulty cable to the sewing motor reference
switch
- Faulty reference switch
- Machine head rough-running or belt tension too
high
- Replace the cable
Replace the reference switch
- Check whether machine head is
rough-running
and belt tension
1052 Sewing motor excess current
- Faulty sewing motor cable
- Faulty sewing motor
- Faulty control
- Replace the sewing motor cable
- Replace the sewing motor
- Replace the control
1053 Sewing motor mains voltage too high
Check the mains voltage
1055 Sewing motor overload
- Sewing motor blocked/seized up
- Faulty sewing motor
- Control faulty
- Eliminate blocking/seizing
- Check the sewing motor
- Check the control
1056 Sewing motor overheat
- Sewing motor seized up
- Faulty sewing motor
- Control faulty
- Eliminate seizing
- Replace sewing motor
- Replace the control
1058
1302
1342
-
1344
Sewing motor speed
- Faulty sewing motor
Failure sewing motor IDMA Autoincrement
Control receives no impulse from impulse
transmitter in the motor
Faulty sewing motor
Internal error
- Replace the sewing motor
- Check the cable from the impulse
transmitter in the motor to the
control
- Switch the machine off and on
again
- Software update
Stepping motors
2101 Stepping motor X-axis time out referencing
- Setting reference switch faulty
- Faulty cable to the reference switch
- Faulty reference switch
- A li g n th e re fe ren c e sw i tc h
- Replace the cable
- Check the reference switch
2102 Stepping motor X-axis faulty current supply
- Stepping motor blocked
- Encoder cable disconnected/faulty
- Encoder faulty
- Remove the blocking
- Check/replace the encoder cable
- Replace the stepping motor
2152 Stepping motor X-axis excess current
- Replace the stepping motor
- Replace the control
2153 Stepping motor X-axis excess voltage
- Mains voltage too high
Check the mains voltage
2155 Stepping motor X-axis overload
- Feeding system rough-running
- Obstacles at feeding movements
- Remove the blocking
- Remove the obstacles/
Adapt the movements