Protective equipment:
n
W
orking clothes
n
Protective gloves
n
Safety goggles
Special tool:
n
16 mm spark plug spanner
1. Pull off the spark plug socket (1).
2. Unscrew the spark plug with a 16 mm spark plug spanner
(2).
3. Operate the recoil starter several times.
4.
CAUTION!
Danger of eye injuries caused by particles
flying around!
– Wear your personal protective equipment
(safety gloves, protective working
clothes, goggles).
Dry the spark plug with a clean cloth or blow it dry with com-
pressed air
.
5. If necessary
, clean the spark plug with a wire brush.
6. Screw the spark plug carefully in by hand and once the
sealing surface of the used spark plug is in contact tighten for
another 1/8 to 1/4 turn with the spark plug spanner
.
7. Plug the spark plug socket back on.
8. Repeat the starting procedure.