EMS Monitoring Functions
FlightDEK-D180 Pilot’s User Guide 9-5
The FlightDEK-D180 has a limited amount non-volatile internal storage for the data log. With a 1-second recording
interval, at least 30 minutes of cumulative data can be recorded; with a 10-second interval, at least 5 hours; with a 30-
second interval, at least 15 hours, and with a 60-second interval, at least 30 hours. When the FlightDEK-D180 internal
storage fills up, new records overwrite the oldest records. To delete the records in internal storage, select ERASE LOG,
ERASE MIN/MAX LOG, or ERASE SNAPSHOT LOG (only available on certain units).
The data format and connection settings for the internally-recorded data are described in the Help Files of the Dynon
Support Program.
EXTERNAL LOGGING
During normal operations, the FlightDEK-D180 constantly streams EFIS flight data via the EFIS DB25 serial output,
and streams EMS engine data via the EMS DB37 serial output. To record and/or display data generated by the
FlightDEK-D180 in real-time a laptop (or other serial port data collection device) must be connected to the serial port(s)
of the FlightDEK-D180.
The data format and connection settings for the streamed data are described on page 11-2.