EasyManua.ls Logo

Dynon Avionics FlightDEK-D180 - Page 95

Dynon Avionics FlightDEK-D180
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EMS Monitoring Functions
FlightDEK-D180 Pilot’s User Guide 9-5
The FlightDEK-D180 has a limited amount non-volatile internal storage for the data log. With a 1-second recording
interval, at least 30 minutes of cumulative data can be recorded; with a 10-second interval, at least 5 hours; with a 30-
second interval, at least 15 hours, and with a 60-second interval, at least 30 hours. When the FlightDEK-D180 internal
storage fills up, new records overwrite the oldest records. To delete the records in internal storage, select ERASE LOG,
ERASE MIN/MAX LOG, or ERASE SNAPSHOT LOG (only available on certain units).
The data format and connection settings for the internally-recorded data are described in the Help Files of the Dynon
Support Program.
EXTERNAL LOGGING
During normal operations, the FlightDEK-D180 constantly streams EFIS flight data via the EFIS DB25 serial output,
and streams EMS engine data via the EMS DB37 serial output. To record and/or display data generated by the
FlightDEK-D180 in real-time a laptop (or other serial port data collection device) must be connected to the serial port(s)
of the FlightDEK-D180.
The data format and connection settings for the streamed data are described on page 11-2.