CV3100 series and MINI series high performance general purpose inverter instruction manual
5-4
Auxiliary Parameter
Function
Code
Name &
Definition
Set Range
Minimun
Unit
Factory
Default
Communi
cation
Address
Modify
P2.00
Starting mode
0:start with starting freq.
1:reserved
1
0
0200H
×
P2.01
Starting freq.
0.00~10.00Hz
0.01Hz
1.00Hz
0201H
○
P2.02
Starting freq.
duration
0.0~10.0s
0.1s
0.0s
0202H
×
P2.03
DC braking
current level
at starting
0.0~100.0%
0.1%
0.0%
0203H
○
P2.04
DC braking
time at
starting
0.1~30.0s (0:immovability of
DC braking)
0.1s
0.0s
0204H
×
P2.05
Accel.&Decel
.way
0:Beeline
1:S-curve
1
0
0205H
○
P2.06
S-curve
starting
duration
proportion
10.0~40.0%
0.1%
20.0%
0206H
×
P2.07
S-curve
ascend/descend
duration
proportion
10.0~80.0%
0.1%
60.0%
0207H
×
P2.08
AVR function
0:inhibitive
1:allowable
1
1
0208H
×
P2.09
Automatic
energy
saving
operation
0:inhibitive
1:allowable
1
0
0209H
×
P2.10
Forward
andreverser
Rotation
dead-zone
interval
0.1~10.0s
0.1s
0.0s
020AH
×
P2.11
Stop mode
0:ramp to stop
1:coast to stop
1
0
020BH
×
P2.12
Starting
frequency for
DC braking
during stop
0.00~20.00Hz
0.01Hz
0.00Hz
020CH
○
P2.13
DC braking
current during
stop
0.0~100.0%
0.1%
0.0%
020DH
○
P2.14
DC braking
time during
STOP
0.1~30.0s (0:No action
during DC Braking)
0.1s
020EH
×