CV3100 series and MINI series high performance general purpose inverter instruction manual
5-4
Auxiliary Parameter
Function
Code
Name &
Definition
Set Range
Minimun
Unit
Factory
Default
Communi
cation
Address
Modify
P2.00
Starting mode
0start with starting freq.
1reserved
1
0
0200H
×
P2.01
Starting freq.
0.0010.00Hz
0.01Hz
1.00Hz
0201H
P2.02
Starting freq.
duration
0.010.0s
0.1s
0.0s
0202H
×
P2.03
DC braking
current level
at starting
0.0100.0
0.1%
0.0
0203H
P2.04
DC braking
time at
starting
0.130.0s (0immovability of
DC braking)
0.1s
0.0s
0204H
×
P2.05
Accel.&Decel
.way
0Beeline
1S-curve
1
0
0205H
P2.06
S-curve
starting
duration
proportion
10.040.0
0.1%
20.0
0206H
×
P2.07
S-curve
ascend/descend
duration
proportion
10.080.0
0.1%
60.0
0207H
×
P2.08
AVR function
0inhibitive
1allowable
1
1
0208H
×
P2.09
Automatic
energy
saving
operation
0inhibitive
1allowable
1
0
0209H
×
P2.10
Forward
andreverser
Rotation
dead-zone
interval
0.110.0s
0.1s
0.0s
020AH
×
P2.11
Stop mode
0ramp to stop
1coast to stop
1
0
020BH
×
P2.12
Starting
frequency for
DC braking
during stop
0.0020.00Hz
0.01Hz
0.00Hz
020CH
P2.13
DC braking
current during
stop
0.0100.0
0.1%
0.0
020DH
P2.14
DC braking
time during
STOP
0.130.0s (0No action
during DC Braking)
0.1s
020EH
×