CV3100 series and MINI series high performance general purpose inverter instruction manual
3-1
Chapter 3 Installation and Wiring
3.1 Installation environment of inverter
3.1.1 Installation environment condition
(1) The inverter shall be installed indoors of perfect ventilation, and the environment
temperature shall be in the range of -10ºC~40ºC, in case that the temperature
exceeds 40ºC, the external air-blast cooling or derating shall be used.
(2) Avoid being installed in the location where suffers from the sun, dust, floatation
fiber and metallic powder.
(3) Never to be installed in the location where corrosive and explosive gas has.
(4) The humidity shall be lower than 95%RHno condensation.
(5) The inverter shall be installed in the location where the plane fixed vibration is less
than 5.9m/s² (0.6g).
(6) The inverter had better be kept far away from the electromagnetic interference
device.
3.1.2 Installation direction and space
(1) Shall be installed vertically usually.
(2) The installation space and min distance are shown as diagram 3-1.
(3) As is shown in diagram 3-2, there shall be a baffler mounted among them, when
several inverters are installed vertically.
Diagram 3-1 Installation space Diagram 3-2 Installation of multi inverters
Inverter Inverter
Baffle plate