EasyManua.ls Logo

EasyDrive MINI-L-2S0015M - User Managing Interface Parameter ( P3.00-P3.09

Default Icon
161 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CV3100 series and MINI series high performance general purpose inverter instruction manual
5-6
Function
Code
Name &
Definition
Set Range
Minimun
Unit
Factory
Default
Communi
cation
Address
Modify
P2.35
Reserved
P2.36
Skip freq.1
0.00~Upper limit freq.
0.01Hz
0.00Hz
0224H
○
P2.37
Skip freq.
band 1
0.0~10.0Hz
0.01Hz
0.00Hz
0225H
○
P2.38
Skip freq.2
0.00~Upper limit freq.
0.01Hz
0.00Hz
0226H
○
P2.39
Skip freq.
band 2
0.0~10.0Hz
0.01Hz
0.00Hz
0227H
○
P2.40
Skip freq.3
0.00~Upper limit freq.
0.01Hz
0.00Hz
0228H
○
P2.41
Skip freq.
band 3
0.0~10.0Hz
0.01Hz
0.00Hz
0229H
○
P2.42
Carrier freq.
selection
1.0~12.0KHz
0.1KHz
022AH
○
P2.43
Carrier
control
method
0:fixed carrier
1:automatic adjustment
1
1
022BH
○
User Managing Interface Parameter
P3.00
LCD language
selection
0:Chinese
1:English
1
0
0300H
○
P3.01
Parameter
initialization
0:disabled
1:revert to factory setting
2: eliminate fault record
1
0
0301H
×
P3.02
Parameter
read-in
protection
0:allowed to modify all
parameters (some of which can
not be changed during inverter
running)
1:only allow to change the
frequency
2:forbidden to modify all
parameters
1
0
0302H
○
P3.03
Factory
password
0~9999
1
0
0303H
○
P3.04
Monitoring
parameter 1
selection
0~18
1
0
0304H
○
P3.05
Monitoring
parameter 2
selection
0~18
1
1
0305H
○
P3.06
Linear
velocity
quotiety
0.01~100.0
0.01
1.00
0306H
○
P3.07
Close loop
display
quotiety
0.01~100.0
0.01
1.00
0307H
○