Loading...
Planning the Installation
Page 10
Table 2: FSL Resistor Bands (without Masking)
Zone State
2k2/4k7 FSL
2k2/2k2 FSL
4k7/4k7 FSL
Tamper
0k0 1k759
0k0 1k759
0k0 3k759
Normal
1k76 4k08
1k76 - 3k08
3k76 - 6k58
Alarm
4k081 8k28
3k081 - 5k28
6k581 - 11k28
Tamper
> 8k28
>5k28
>11k28
If a detector is able to report masking, connect the detector as shown in Figure 2. The
detector must signal masking by closing both the Alarm and Fault contacts together. If the
detector closes the Fault contact only, the control unit reports this as a detector fault.
Figure 2. FSL Connections with Masking
4-wire CC
This uses a separate pair of wires for the alarm and tamper contacts. No end-of-line
resistors are used. Selecting 4-wire CC halves the maximum number of wired zones the
device supports.
2-wire CC
This uses a single pair of wires for each detector. No end-of-line resistors are used.
Alarm
Tamper
Fault/trouble
EOL
Tamper
Tamper
Mask
Alarm
Fault
Normal