Getting Started
Page 14
Entering the Installer menu
Entering the Installer menu allows you to configure the system using the options provided.
While you are logged in, the system will not generate alarms. You are, for example, able to
open the lid of the control unit without generating an alarm. All Hold-Up Alarms (HUAs),
fire-alarm zones, 24-hour zones and tampers are disabled.
To enter the Installer menu:
1. Make sure the system is fully unset and showing the standby screen. For example:
10:15 Fri 01/01/2016
i-on Style-EU
2. Enter the Installer code, as specified when the control unit was first configured:
Enter Access Code:
3. You may prompted to enter a user code (default 1234):
User Code Required:
This is displayed if you have not used the Installer menu with the previous 30
minutes, or if the system has been armed and disarmed within that period. You can
disable this feature using System Options User Access User Code Required (see
page 61). You cannot enter a Set Only user code.
4. The first option in the menu is displayed:
INSTALLER MENU
Detectors/Devices
5. Press or to display the next option in the menu, then press or to select
that option. Continue this process until you have reached the sub-option you require.
Saving changes
Changes are saved only when you leave the Installer menu. If you remove all power
before leaving the Installer menu, changes will not be saved. Note that this does not apply
if you restore factory defaults; that change takes place immediately.