All the features of the Standard feature package.
LCD screen that displays surge count.
Reset button to RESET the Surge Counter to zero.
33..22..44 PPoowweerr XXppeerrtt SSPPDD FFeeaattuurree PPaacckkaaggee
The Eaton Power Xpert SPD feature package display is shown in Figure 18.
FFiigguurree 1188.. PPoowweerr XXppeerrtt SSPPDD DDiissppllaayy
The Power Xpert SPD has the following features:
All features of the Standard with Surge Counter feature package including advanced monitoring and
communication.
Power Xpert Gateway (PXG900) with firmware version 4.6.4 and higher are Modbus TCP supported and
configurable with the ability to receive email notifications. Modbus TCP/IP must be enabled on the PX SPD
prior to use.
LCD main menu options include the following:
SPD status - surge event logs
Event logs all events including phase protection percentage, phase loss, alarm status, power on/off,
and low, medium and high level surges.
Settings - includes device set up, changing the password and the option of giving the device a unique
name.
Identification - information on the device.
One form C relay contact rated at 150 Vac at 0.46 A, 30 Vdc at 1 A. Normal operating conditions. N.O. =
OPEN. N.C = CLOSED. Loss of protection on any phase or loss of power. N.O. = CLOSED. N.C. = OPEN.
Audible alarm with push any button to silence.
EMI/RFI filtering.
Remote monitoring via web UI, Modbus TCP/IP or BACnet/IP protocols. Modbus, BACnet and HTTP are
initially disabled for cybersecurity purposes.
Phase surge event counters.
Time/date stamp event logs.
Green LEDs: Illumination indicates the phase is fully protected (100%), and operating normally, with all
protection active and available. Green LEDs also indicate neutral to ground protection on units with a
neutral wire. Green LEDs do not indicate on/off status of power.
Operating Features

Table of Contents

Other manuals for Eaton SPD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton SPD Series and is the answer not in the manual?

Eaton SPD Series Specifications

General IconGeneral
TypeSurge Protective Device
Voltage Rating120/240V, 208Y/120V, 480Y/277V
Surge Current CapacityUp to 200kA
Modes of ProtectionL-N, L-G, N-G
Operating Frequency50/60Hz
CertificationsUL 1449
SPD TypeType 1, Type 2
Maximum Surge CurrentUp to 200kA
Nominal Discharge Current (In)10kA, 20kA
Short Circuit Current Rating (SCCR)Up to 200kA
Enclosure TypeNEMA 1
MountingPanel Mount
StandardsUL 1449, IEEE C62.41
DiagnosticsVisual Indicators
Remote MonitoringOptional
Maximum Discharge Current (Imax)Up to 200kA