MAINTENANCE
STEP 5 – OIL FILTER
Dismantle the used oil filter by an oil filter spanner.
Used filters must be disposed in accordance with the applicable country
regulations. Improper disposal of used filters represents a hazard to the
environment!
Take the new oil filter, put a little oil onto the rubber seal and tighten the oil
filter manually.
Do not use any tools to fit the oil filter as they could damage it!
STEP 6 – OIL
Add oil to the engine. Fill a maximum of 30 litres of oil through the filler neck.
Use a funnel to fill the engine.
Check the oil level on the dipstick to ensure that the engine is not overfilled.
After checking the oil level, fasten the oil cap by a water pump pliers.
STEP 7 – NEW SPARK PLUGS
The temperatures of the spark plugs and the cylinder head have now equalised.
Fasten the new spark plugs by a torque wrench with a 20.8 mm spark plug
insert and put the spark plug cap back on.
Torque: 18 Nm.
Fig. 6.09