EasyManua.ls Logo

EC POWER XRGI 9 - SCHRITT 5 - Plug for Measuring Point; SCHRITT 6 - Oil Filter; SCHRITT 7 - Oil

Default Icon
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE
STEP 5 – PLUG FOR MEASURING POINT
Depending on the type of exhaust gas pipe, consider replacing the plug in
the exhaust gas opening on the exhaust gas pipe upstream of the Power
Unit.
STEP 6 – OIL FILTER
Dismantle the used oil filter by an oil filter spanner.
Used filters must be disposed in accordance with the applicable country
regulations. Improper disposal of used filters represents a hazard to the
environment!
Take the new oil filter, put a little oil onto the rubber seal and tighten the oil
filter manually.
Do not use any tools to fit the oil filter as they could damage it!
STEP 7 – OIL
Add oil to the engine. Fill a maximum of 50 litres of oil through the filler neck.
Use a funnel to fill the engine.
Check the oil level on the dipstick to ensure that the engine is not overfilled.
After checking the oil level, fasten the oil cap by a water pump pliers.
STEP 8 – NEW SPARK PLUGS
The temperatures of the spark plugs and the cylinder head have now equalised.
Fasten the new spark plugs by a torque wrench with a 20.8 mm spark plug
insert and put the spark plug cap back on.
Torque: 18 Nm.
Fig. 7.20
Fig. 7.21
Fig. 7.22
Fig. 7.23
Fig. 7.24
Fig. 7..25
39

Table of Contents

Other manuals for EC POWER XRGI 9

Related product manuals