FibroScan
FIBROSCAN
502
TOUCH
USER
MANUAL
[3
.
ELECTROMAGNETIC
IMMUNITY
(2)
The
FibroScan
502
TOUCH
is
designed
for
use
in
the
electromagnetic
environment
defined
below.
The
customer
or
the
user
of
the
FibroScan
502
TOUCH
must
ensure
that
it
is
used
in
this
type
of
environment.
60601
Immunity
test
|
IEC
Compliance
Electromagnetic
Environment
-
Directives
|
test
level
Portable
and
cellular
RF
communication
equipment
must
be
kept
far
away
from
the
FibroScan
device
502
TOUCH
(including
its
cables),
at
a
distance
greater
than
the
recommended
distance
calculated
using
the
|
equation
applicable
to
the
emitter
frequency.
Recommended
separation
distance
Conducted
RF
3
Vrms
3
Vrms
d=1.17
VP
IEC
61000-4-6
|
150
kHz
to
80
MHz
Radiated
RF
3V/m
3
Vim
d=117VP
IEC
61000-4-3
|
80
MHz
80
MHz
to
800
MHz
to
2.5
GHz
d=
2.33
VP
800
MHz
to
2.5
GHz
where
P
is
the
maximum
emitter
power
in
watts
|
(W),
as
specified
by the
emitter
manufacturer,
and
dis
the
recommended
separation
distance
in
meters
(m).
The
strength
of
EM
fields
for
fixed
emitters,
as
determined
by
a
study.
2The
electromagnetic
range
of
the
site
must
be
within
the
compliance
level
reguired
in
each
freguency
band.
3
|
Interference
may
occur
in
the
vicinity
of
devices
bearing
the
following
symbol:
(©)
NOTE
1:
At
80
MHz
and
800
MHz,
the
higher
frequency
band
is
applicable.
NOTE
2:
These
recommendations
may
not
be
applicable
in
all
cases.
Electromagnetic
propagation
is
affected
by
absorption
and
reflection
caused
by
structures,
objects
and
individuals.
NOTE
3:
The
use
of
cables
and/or
accessories
not
specified
in
the
User
Manual
may
reduce
the
device's
immunity.
2.
The
strength
of
EM
fields
for
fixed
emitters
such
as
commercial
AM/FM
radio
broadcasting
services,
television,
cellular
telephone
services,
radio
detection,
air
traffic
control,
radio
paging
receivers
and
GSM
services
cannot
be
accurately
predicted.
To
assess
the
EM
environment
caused
by
fixed
emitters,
a
site
EM
study
must
be
conducted.
If
the
field
strength
measured
at
the
location
where
the
FibroScan
device
502
TOUCH
is
used
exceeds
the
compliance
levels
mentioned
above,
correct
operation
of
the
FibroScan
device
502
TOUCH
must
be
checked.
If
abnormal
performance
is
observed,
additional
measurements
may
be
required
after,
for
example
reorienting
or
moving
the
FibroScan
502
TOUCH.
3.
In
the
frequency
range
150
kHz
80
MHz,
field
strengths
should
ideally
be
lower
than
3
V/m.
E300M017.4
03/2017
-
ECHOSENSTM
AND
FIBROSCAN®
ARE
TRADEMARKS
©
COPYRIGHT
ECHOSENS
-
ALL
RIGHTS
RESERVED
67