4. Measurement procedure gas analysis
4.1 Gas analysis
The measurement procedure for gas analysis can be used for most control measurements in
order to determine the gas components, temperatures and ratios in the measured
combustion process.
Design of the measurement displays gas analysis 1..3
The following measurement displays are available for the gas analysis procedure:
Measurement display: Gas analysis 1 + 2
Measurement display: Gas analysis 3
Switch-off CO-Sensor
key <F3>
Symbol cooler ON /OFF
Hotkey key <F1>
Hotkey key <F4>
Store and print values
key <F2>
The following functions are available in all 3 measurement displays:
Pressing <F1> enables to switch, from the values display, to a menu point selected before or
on Standby“ (see chapter Adjustments). Possible menu points are: Soot...Oil trace, Data
processing, View memory, Display values, Fuel type, Efficiency (K), Internal, Adjustments.
Furthermore you can switch back from any random menu point to the values display with
<F1>.
Press <F2> to print out the values simultaneously to their recording in the intermediate
memory.
Press <F3> to cut the CO sensor from the gas path so that it is protected against too high
concentrations.
Pressing <F4> also enables to switch, from the values display, to a menu point selected
before or on „Standby“ (see chapter Adjustments).
1
2 3
4
5
1
2
3
4
5

Table of Contents